Models
KM-1301SAH/3
KM-1301SWH/3
KM-1301SRH/3
Stackable Crescent Cuber
Hoshizaki America, Inc.
SERVICE MANUAL
Number: 73169
Issued:1-21-2009
Revised: 8-6-2009
Seitenansicht 0
1 2 3 4 5 6 ... 83 84

Inhaltsverzeichnis

Seite 1 - Hoshizaki

Hoshizaki “A Superior Degree of Reliability” www.hoshizaki.com Models KM-1301SAH/3 KM-1301SWH/3 KM-1301SRH/3 Stackable Crescent Cuber Hoshizaki Ame

Seite 2

104. KM-1301SWH3 (water-cooled)Note: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 208-230/6

Seite 3 - CONTENTS

115. KM-1301SRH (remote air-cooled)Note: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 208-2

Seite 4

126. KM-1301SRH3 (remote air-cooled)Note: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 208-

Seite 5

13B. Condenser Unit1. URC-14FUnit: inches (mm)

Seite 6 - Important Safety Information

14 SPECIFICATIONSMODEL: URC-14FAC SUPPLY VOLTAGE 115/60/1 (Connection to Icemaker) FAN MOTOR 115 V Total 2.6FLA 130WEXTERIOR DIMENSIONS (WxDxH) 35-11

Seite 7 - A. Icemaker

15II. General InformationA. Construction1. KM-1301SAH, KM-1301SAH3 (air-cooled)Evaporator AssemblySpray TubesInlet Water ValveWater Supply InletHot Ga

Seite 8 - 2. KM-1301SAH3 (air-cooled)

162. KM-1301SWH, KM-1301SWH3 (water-cooled)Evaporator AssemblySpray TubesInlet Water ValveWater Supply InletHot Gas ValveJunction BoxWater Regulating

Seite 9 - 3. KM-1301SWH (water-cooled)

173. KM-1301SRH, KM-1301SRH3 (remote air-cooled)Evaporator AssemblySpray TubesInlet Water ValveWater Supply InletHot Gas ValveJunction BoxesReceiver T

Seite 10 - 4. KM-1301SWH3 (water-cooled)

18B. Sequence of OperationIMPORTANTThis unit utilizes a thermostatic bin control. For operation, the K4 jumper (4A4883G01) must be in place on the con

Seite 11

19de-energize. For the rst 5 minutes, CB will not accept a signal from F/S. This minimum 5-minute freeze time is short cycle protection for Comp. At

Seite 12

2IMPORTANTOnly qualied service technicians should install, service, and maintain the icemaker. No service or maintenance should be undertaken until t

Seite 13 - B. Condenser Unit

202. Sequence Flow Chart•WVtime:6min.orthelengthofharvestminus0or50 sec. (S4 dip switch 7), whichever is shorter. DO NOT ADJUST S4 dip s

Seite 14 - SPECIFICATIONS

21C. Control Board•A Hoshizaki exclusive solid-state control board is employed in KM-1301SAH/3, KM-1301SWH/3, and KM-1301SRH/3, Stackable Crescent Cu

Seite 15 - A. Construction

221. Control Board LayoutControl BoardPart Number 2A3792-01"G" Control Board"ALARM RESET" Button"OUTPUT TEST" Button(use

Seite 16

232. Featuresa) Maximum Water Supply Period - 6 minutesThe inlet water valve will be open during harvest for 6 minutes or the length of harvest minus

Seite 17

24f) LED Lights and Audible Alarm SafetiesAt startup, a 5-second delay occurs while the control board conducts an internal timer check. A beep occurs

Seite 18 - IMPORTANT

253. Controls and AdjustmentsCAUTIONDip switches are factory set. Failure to maintain factory settings may adverselyaffect performance and warranty co

Seite 19

26c) Pump-Out Timer (S4 dip switch 3 & 4)CAUTIONDo not adjust S4 dip switch 3 off and S4 dip switch 4 on for this model. Otherwise, pump motor doe

Seite 20 - 2. Sequence Flow Chart

27e) Harvest Pump Timer (S4 dip switch 7)CAUTIONFactory set for proper operation. Do not adjust. Adjustment outside of the factory default setting may

Seite 21 - C. Control Board

28h) Float Switch Control (S5 dip switch 1)CAUTIONDo not adjust. This must be left in the factory default position or the unit will not operate corre

Seite 22 - "G" Control Board

29D. Bin ControlCAUTIONWhen the ambient temperature is below 45°F (7°C), the thermostatic bin control switch opens and shuts down the icemaker even if

Seite 23

3CONTENTSImportant Safety Information ... 6I. Specicati

Seite 24

30III. Technical InformationA. Water Circuit and Refrigeration Circuit1. KM-1301SAH, KM-1301SAH3 (air-cooled)Water SupplyCleaning ValveFloat SwitchDra

Seite 25

312. KM-1301SWH, KM-1301SWH3 (water-cooled)Water SupplyCleaning ValveFloat SwitchDrainCheck ValveExpansion ValvesCompressorHot Gas ValveCheck ValvesHi

Seite 26

323. KM-1301SRH, KM-1301SRH3 (remote air-cooled)Water SupplyCleaning ValveFloat SwitchDrainCheck ValveExpansion ValvesCompressorHot Gas ValveCheck Val

Seite 27

33B. Wiring Diagrams1. Auxiliary Code T-0, U-0 a) KM-1301SAH (air-cooled)Auxiliary Code T-0, U-0Transformer Output 10.5V at 115V** High Pressure Switc

Seite 28

34b) KM-1301SWH (water-cooled)Auxiliary Code T-0, U-0*Transformer Output 10.5V at 115V* High Pressure SwitchCut-out 384±21 PSIG Cut-in 284±21 PSIG0

Seite 29 - G. Control Switch

35c) KM-1301SRH (remote air-cooled)Auxiliary Code T-0, U-0Transformer Output 10.5V at 115V* High Pressure SwitchCut-out 412±21 PSIG Cut-in 327±21 PSIG

Seite 30 - III. Technical Information

36d) KM-1301SAH3 (air-cooled) and KM-1301SWH3 (water-cooled)Auxiliary Code T-0, U-0Transformer Output 10.5V at 115V** High Pressure SwitchAir-Cooled M

Seite 31 - Pump Timer

37e) KM-1301SRH3 (remote air-cooled)Auxiliary Code T-0, U-0*Transformer Output 10.5V at 115V* High Pressure SwitchCut-out 412±21 PSIG Cut-in 327±21 PS

Seite 32

382. Auxiliary Code U-1 and Later a) KM-1301SAH (air-cooled) Auxiliary Code U-1 and LaterTransformer Output 10.5V at 115V** High Pressure SwitchCut-ou

Seite 33 - B. Wiring Diagrams

39b) KM-1301SWH (water-cooled) Auxiliary Code U-1 and Later*Transformer Output 10.5V at 115V* High Pressure SwitchCut-out 384±21 PSIG Cut-in 284±21 P

Seite 34 - Cut-in 284±21 PSIG

4e) Harvest Pump Timer (S4 dip switch 7) ... 27f) Factory Use (S4 dip switch 8) ...

Seite 35 - Cut-in 327±21 PSIG

40c) KM-1301SRH (remote air-cooled)Auxiliary Code U-1 and Later*Transformer Output 10.5V at 115V* High Pressure SwitchCut-out 412±21 PSIG Cut-in 327±2

Seite 36 - 10.5V at 115V

41d) KM-1301SAH3 (air-cooled) and KM-1301SWH3 (water-cooled)Auxiliary Code U-1 and Later*Transformer Output 10.5V at 115V* High Pressure SwitchAir-Coo

Seite 37

42e) KM-1301SRH3 (remote air-cooled)Auxiliary Code U-1 and Later*Transformer Output 10.5V at 115V* High Pressure SwitchCut-out 412±21 PSIG Cut-in 327±

Seite 38

43C. Performance Data1. KM-1301SAH (air-cooled)Note:1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used

Seite 39

442. KM-1301SAH3 (air-cooled)Note:1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference onl

Seite 40

453. KM-1301SWH (water-cooled) Note:1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference o

Seite 41

464. KM-1301SWH3 (water-cooled) Note:1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference

Seite 42

47Note:1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.2. We reserve the right t

Seite 43 - C. Performance Data

486. KM-1301SRH3 (remote air-cooled)Note:1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for refere

Seite 44

49IV. Service Diagnosis WARNING1. This unit should be diagnosed and repaired only by qualied service personnel to reduce the risk of death, electric

Seite 45

5V. Removal and Replacement of Components ... 65A. Service for Refrigerant Lines ...

Seite 46

503) 1-Minute Fill Cycle – LED 4 is on. WV and X2 relay (auxiliary code T-0, U-0), X11 relay (auxiliary code U-1 and later) energize and the 1-minute

Seite 47

515) Freeze Cycle – LED 1 is on. Comp and FMR remain energized, PM energizes or remains energized depending on harvest pump timer (S4 dip switch 7) se

Seite 48

52Diagnosis: If PM does not reverse, check to see if CB S4 and S5 dip switch settings are in the factory default position. If S4 dip switch 3 and 4 ar

Seite 49 - A. Diagnostic Procedure

53B. Control Board CheckBefore replacing a control board that does not show a visible defect and that you suspect is bad, always conduct the following

Seite 50

54C. Bin Control CheckTo check the thermostatic bin control, follow the steps below.CAUTIONWhen the ambient temperature is below 45°F (7°C), the therm

Seite 51

558) Reconnect the black oat switch connector to the control board BLACK K5 connector, then replace the control box cover in its correct position.9)

Seite 52

567) Wipe down the oat switch assembly's housing, shaft, oat, and retainer rod with a mixture of 1 part Hoshizaki "Scale Away" and 25

Seite 53 - B. Control Board Check

57F. Diagnostic Charts1. No Ice ProductionProblem Possible Cause Remedy[1] The icemaker will not start.a) Power Supply 1. Off, blown fuse, or tripped

Seite 54 - C. Bin Control Check

58Problem Possible Cause Remedy[1] The icemaker will not start. (continued)h) Transformer 1. Coil winding open or shorted.1. Replace.i) Wiring to Cont

Seite 55

59Problem Possible Cause Remedy[3] Compressor will not start or stops operating.a) Magnetic Contactor 1. Bad contacts. 1. Check for continuity and rep

Seite 56 - E. Thermistor Check

6Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,

Seite 57 - F. Diagnostic Charts

60Problem Possible Cause Remedy[7] Fan motor will not start, or is not operating (except water-cooled model).a) Fan Motor 1. Motor winding open. 1. Re

Seite 58

61Problem Possible Cause Remedy[1]Freeze cycle time is too long. (continued)f) Thermistor 1. Loose or disconnected.1. Reattach or connect. See "I

Seite 59

62Problem Possible Cause Remedy[3]Other. a) Ice Cube Guide 1. Out of position. 1. Place in position.b) Thermostatic Bin Control 1. Bulb out of positi

Seite 60 - 2. Evaporator is Frozen Up

63Problem Possible Cause Remedy[2] Harvest cycle time is long.a) Water Supply 1. Water temperature too cold.1. Increase temperature.b) Thermistor 1. O

Seite 61

64Problem Possible Cause Remedy[2] Cloudy or irregular cubes.a) Evaporator 1. Frozen up. 1. See chart 2. 2. Scaled up. 2. Clean3. Damaged. 3. Replace

Seite 62 - 3. Low Ice Production

65V. Removal and Replacement of Components WARNING1. This unit should be diagnosed and repaired only by qualied service personnel to reduce the risk

Seite 63 - 4. Abnormal Ice

662. Brazing WARNING1. R-404A itself is not ammable at atmospheric pressure and temperatures up to 176°F (80°C).2. R-404A itself is not explosive or

Seite 64 - 5. Other

673) Allow the vacuum pump to pull down to a 29.9" Hg vacuum. Evacuating period depends on pump capacity.4) Close the low-side valve and high-sid

Seite 65

687) Remove the compressor. Unpack the new compressor package. 8) Attach the rubber grommets of the prior compressor to the new compressor.9) Place th

Seite 66

698) Use an electronic leak detector or soap bubbles to check for leaks. Add a trace of refrigerant to the system (if using an electronic leak detecto

Seite 67

7I. SpecicationsA. Icemaker1. KM-1301SAH (air-cooled)Note: We reserve the right to make changes in specications and design without prior notice.AC S

Seite 68

7010) Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the nameplate for the required refrigerant char

Seite 69

71F. Removal and Replacement of Air-Cooled CondenserCAUTION1. Always install a new drier every time the sealed refrigeration system is opened. 2. Do n

Seite 70

72G. Removal and Replacement of Water-Cooled CondenserCAUTION1. Always install a new drier every time the sealed refrigeration system is opened. 2. Do

Seite 71

73H. Removal and Replacement of Remote Air-Cooled CondenserCAUTION1. Always install a new drier every time the sealed refrigeration system is opened.

Seite 72

74I. Removal and Replacement of Water Regulating Valve (water-cooled model)CAUTION1. Always install a new drier every time the sealed refrigeration sy

Seite 73

7518) Check for water leaks.19) Replace the panels in their correct positions.20) Turn on the power supply.J. Adjustment of Water Regulating Valve (wa

Seite 74 - (water-cooled model)

768) Braze all ttings with nitrogen gas owing at a pressure of 3 to 4 PSIG. 9) Use an electronic leak detector or soap bubbles to check for leaks. A

Seite 75 - Top View

7711) Connect the white thermistor connector through the bushing of the control box to the control board WHITE K3 connector.CAUTIONDo not cut the lead

Seite 76 - Fig. 3

7810) Turn on the power supply.11) Check for leaks.12) Replace the front panel in its correct position.13) Turn on the power supply.O. Removal and Rep

Seite 77

79P. Removal and Replacement of Control BoardWhen replacing a control board follow the precautions below.CAUTION1. The control board is fragile; handl

Seite 78

8Note: We reserve the right to make changes in specications and design without prior notice.2. KM-1301SAH3 (air-cooled)AC SUPPLY VOLTAGE 208-230/60/3

Seite 79

80CLOSED POSITION OPEN POSITIONVI. Cleaning and MaintenanceIMPORTANTEnsure all components, fasteners, and thumbscrews are securely in place after any

Seite 80 - VI. Cleaning and Maintenance

811. Cleaning Procedure1) Dilute 27 . oz. (800 ml) of Hoshizaki "Scale Away" with 5 gal. (19 l) of warm water. 2) Remove all ice from the e

Seite 81

8218) Replace the front panel in its correct position.19) Turn on the power supply to ll the water tank with water.20) Turn off the power supply afte

Seite 82

83B. Maintenance InstructionsIMPORTANTThis icemaker must be maintained individually, referring to the instruction manual and labels provided with the

Seite 83 - B. Maintenance Instructions

845) Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring. While holding the valve open, blow

Seite 84

93. KM-1301SWH (water-cooled) Note: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 208-230/60