Seitenansicht 15
15
Fig. 4
KM-61BAH, KM-101BAH, KM-151BAH
2-inch (5-cm) air
gap
Drain
Floor
Icemaker Water Supply
Inlet 1/2” FPT
Icemaker Drain Outlet
3/4” FPT
Icemaker Water Supply
Line Shut-off Valve
To approved oor drain
Icemaker Water Supply
Line Drain Valve
1/4” fall
per foot
Minimum 3/4” Nominal
ID Hard Pipe
Minimum 1/4” Nominal ID
Copper Water Tubing
Trap
An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is suf cient extra water supply line and drain line for the appliance to be
pulled out for service.
Be sure there is suf cient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the
drain.
Seitenansicht 15