Hoshizaki KM-101BAH Bedienungsanleitung Seite 28

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 27
26
6) Close the door.
7) Place the air lter in its correct position.
8) Close the icemaker water supply line drain valve.
3. On water-cooled model only, remove the water from the water-cooled condenser:
1) Make sure the control switch is in the “OFF” position and the appliance is unplugged
from the electrical outlet.
2) Remove the rear cover.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop
system, also close the condenser return line shut-off valve. See Fig. 5 or 6.
3) Open the condenser water supply line drain valve. If connected to a closed loop
system, also open the condenser return line drain valve.
4) Attach a compressed air or carbon dioxide supply to the condenser water supply line
drain valve.
5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer
underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.
Note: Be sure to close the water regulating valve as before.
6) Close the condenser water supply line drain valve. If connected to a closed loop
system, also close the condenser return line drain valve.
7) Replace the rear cover in its correct position.
IV. Disposal
The appliance contains refrigerant and must be disposed of in accordance with applicable
national, state, and local codes and regulations. Refrigerant must be recovered by properly
certi ed service personnel.
IMPORTANT
The insulation foaming agent used for the unit body contains ammable gas
cyclopentane. With this in mind, dispose of the product properly.
Seitenansicht 27